Bafang error 41: Battery total voltage too high

Bafang CAN systems (M400/M500/M600/M620, DP C18 CAN, 850C/860C CAN)WarningRide with caution

The battery's BMS reports a total pack voltage above its limit. Riders see this right after charging or when a charger of the wrong voltage was used. The system limits or blocks power until the voltage drops.

Drive systemBafang CAN systems (M400/M500/M600/M620, DP C18 CAN, 850C/860C CAN)
SeverityWarning
Keep riding?Ride with caution
Typical costA correct charger EUR/USD 40-100; BMS repair EUR/USD 80-150.

Likely causes

How to fix Bafang error 41

  1. Disconnect the charger and check its rated output matches the battery
  2. Ride on low assist for a few minutes to lower the voltage, then power cycle
  3. Measure the pack voltage; if it is above the rated maximum, stop using that charger
  4. Have the BMS checked if the measured voltage is normal but the code persists
Go to a dealer if: Go to a shop if the pack voltage is normal on a multimeter but the code stays; the BMS is misreading.
Warranty: Battery warranty applies to BMS faults; damage from a wrong charger is excluded.
Typical cost: A correct charger EUR/USD 40-100; BMS repair EUR/USD 80-150.
Still stuck? Take a photo of the display and show it to a local e-bike workshop. Bring the bike's system name (e.g. Bosch Performance Line CX) and the exact code; that saves diagnostic time and money.

Frequently asked

Can I reset error 41?

It clears as the voltage drops. Power cycle after a short ride.

Can I keep riding?

Yes once cleared, but fix the charging issue first.

Warranty?

Only if the BMS is at fault.